We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Only %1 left
SKU
COVID-19, Flu A/B, RSV Multiplex One-Step RT-qPCR Kit, IVD
NZYtech´s COVID-19, Flu A/B, RSV Multiplex One-Step RT-qPCR Kit, IVD provides the complete set of reagents and probes to qualitatively detect the SARS-CoV-2, RSV and/or Influenza genomes, through common real-time PCR platforms.
NZYtech´s COVID-19, Flu A/B, RSV Multiplex One-Step RT-qPCR Kit, IVD provides the complete set of reagents and probes to qualitatively detect the SARS-CoV-2, RSV and/or Influenza genomes, through common real-time PCR platforms. SARS-CoV-2 is identified by detecting RT-qPCR targets located in RdRp and N genes. In contrast, Influenza A and Influenza B viruses are detected through the amplification of targets located in M1 and NS2 genes, respectively. RSV virus is detected through the amplification of target located in L gene and the human ribonuclease P (RNase P, RP) gene. In case the IFU is not available in your official country language, please contact us – info@NZYtech.com so that we can proceed with the translation. Please see languages available below.
High Sensitivity: Early virus detection and diagnosis, detects as low as 250 copies/mL of SARS-CoV-2, 375 copies/mL of Influenza A, 375 copies/mL of Influenza B viral RNA and 375 copies/mL of RSV viral RNA (LoD) sample.
High Throughput: Up to 93 clinical samples (96-well plate); up to 381 clinical samples (384-well plate)
High Specificity: Proven by in silico analysis as well as wet lab testing
Flexibility: Assay validated on widely used qPCR instruments including Applied Biosystem® 7500 FAST, Applied Biosystem® QuantStudio 5, Roche Life Science LightCycler® 96 System, Bio-Rad® CFX Opus
Fast Time: < 1h from nucleic acid extraction to results.
Minimal Sample Input: As low as 2 μL sample needed.
Find the IFU for your product batch
High Sensitivity: Early virus detection and diagnosis, detects as low as 250 copies/mL of SARS-CoV-2, 375 copies/mL of Influenza A, 375 copies/mL of Influenza B viral RNA and 375 copies/mL of RSV viral RNA (LoD) sample.
High Throughput: Up to 93 clinical samples (96-well plate); up to 381 clinical samples (384-well plate)
High Specificity: Proven by in silico analysis as well as wet lab testing
Flexibility: Assay validated on widely used qPCR instruments including Applied Biosystem® 7500 FAST, Applied Biosystem® QuantStudio 5, Roche Life Science LightCycler® 96 System, Bio-Rad® CFX Opus
Fast Time: < 1h from nucleic acid extraction to results.
Minimal Sample Input: As low as 2 μL sample needed.
Find the IFU for your product batch
Shipping Conditions | Blue Ice |
---|---|
Storage Conditions | -85 °C to -15 °C |
Application | In Vitro Diagnostics (IVD) |
Format | Liquid |
Product Category | Predesigned qPCR assays |
Compatibility | AB™ 7500, AB™ QuantStudio 5, Bio-Rad® Opus, Roche Life Science LightCycler® 96 System |
Marking | CE-IVD |
Target Species | Influenza A/B, RSV, SARS-CoV-2 |
Sample Material | RNA |
Protocol time | Approx. 60 min. (from extracted NA to result) |
Number of targets | Hexaplex |
Internal Control | No |
Detection Method | Probe Based |
- NZYSupreme Multiplex One-step RT-qPCR Probe Master Mix (2x)
- COVID-19, Flu A/B, RSV Primer & Probe Mix (10x) (Texas Red®, FAM™, HEX™ and Cy5™ labelled)
- COVID-19, Flu A/B, RSV Positive Control 1 (SARS-CoV-2 ORF1ab, Influenza B NS2, RSV L and human RP genes)
- COVID-19, Flu A/B, RSV Positive Control 2 (SARS-CoV-2 N, Influenza A M1, RSV L and human RP genes)
- No-Template Control
- COVID-19, Flu A/B, RSV Primer & Probe Mix (10x) (Texas Red®, FAM™, HEX™ and Cy5™ labelled)
- COVID-19, Flu A/B, RSV Positive Control 1 (SARS-CoV-2 ORF1ab, Influenza B NS2, RSV L and human RP genes)
- COVID-19, Flu A/B, RSV Positive Control 2 (SARS-CoV-2 N, Influenza A M1, RSV L and human RP genes)
- No-Template Control
Shipping Conditions | Blue Ice |
---|---|
Storage Conditions | -85 °C to -15 °C |
Application | In Vitro Diagnostics (IVD) |
Format | Liquid |
Product Category | Predesigned qPCR assays |
Compatibility | AB™ 7500, AB™ QuantStudio 5, Bio-Rad® Opus, Roche Life Science LightCycler® 96 System |
Marking | CE-IVD |
Target Species | Influenza A/B, RSV, SARS-CoV-2 |
Sample Material | RNA |
Protocol time | Approx. 60 min. (from extracted NA to result) |
Number of targets | Hexaplex |
Internal Control | No |
Detection Method | Probe Based |
Shipping Conditions | Blue Ice |
---|---|
Storage Conditions | -85 °C to -15 °C |
Application | In Vitro Diagnostics (IVD) |
Format | Liquid |
Product Category | Predesigned qPCR assays |
Compatibility | AB™ 7500, AB™ QuantStudio 5, Bio-Rad® Opus, Roche Life Science LightCycler® 96 System |
Marking | CE-IVD |
Target Species | Influenza A/B, RSV, SARS-CoV-2 |
Sample Material | RNA |
Protocol time | Approx. 60 min. (from extracted NA to result) |
Number of targets | Hexaplex |
Internal Control | No |
Detection Method | Probe Based |
MSDS
Material Safety Data Sheets
No files currently available for download
CoA
Certificate of Analysis