SKU
MD05131
Acinetobacter baumannii qPCR Kit
Acinetobacter baumannii qPCR Kit is designed for the in vitro detection of A. baumannii genomes.
Availability
Ready to Ship
Acinetobacter baumannii is a typically short, almost round, rod-shaped (coccobacillus) Gram-negative bacterium almost exclusively isolated from hospital environments. Therefore, it can be an opportunistic pathogen in humans, affecting people with compromised immune systems, and is becoming increasingly important as a hospital-derived (nosocomial) infection.
Acinetobacter baumannii qPCR Kit is designed for the in vitro detection of A. baumannii genomes. The kit is built to have the broadest possible detection profile whilst remaining specific to A. baumannii. Thus, this kit has been designed for the specific (inclusivity) and exclusive (exclusivity) in vitro detection of this species. The primers and probe sequences have very high (>95%) homology with a broad range of A. baumannii genomes based on a comprehensive bioinformatic analysis with all reference data within the NCBI database. Other closely related species are not detected. Real-time PCR detection methods have been used in several studies to identify A. baumannii genomes (McConnell M. et al 2011).
If required, a complementary kit for the detection of an endogenous gene of the species from which samples are being extracted is available at NZYTech (see Human). The complementary usage of an Endogenous Detection reaction provides a solid confirmation that nucleic acids were properly extracted from the selected biological matrix. If you require further information or have a specific question about the detection profile of this kit, please send an e-mail to info@nzytech.com and our scientific team will answer your question. This kit is designed to be used by trained users in a suitable molecular biology laboratory environment.
Acinetobacter baumannii qPCR Kit is designed for the in vitro detection of A. baumannii genomes. The kit is built to have the broadest possible detection profile whilst remaining specific to A. baumannii. Thus, this kit has been designed for the specific (inclusivity) and exclusive (exclusivity) in vitro detection of this species. The primers and probe sequences have very high (>95%) homology with a broad range of A. baumannii genomes based on a comprehensive bioinformatic analysis with all reference data within the NCBI database. Other closely related species are not detected. Real-time PCR detection methods have been used in several studies to identify A. baumannii genomes (McConnell M. et al 2011).
If required, a complementary kit for the detection of an endogenous gene of the species from which samples are being extracted is available at NZYTech (see Human). The complementary usage of an Endogenous Detection reaction provides a solid confirmation that nucleic acids were properly extracted from the selected biological matrix. If you require further information or have a specific question about the detection profile of this kit, please send an e-mail to info@nzytech.com and our scientific team will answer your question. This kit is designed to be used by trained users in a suitable molecular biology laboratory environment.
Shipping Conditions | Room Temperature |
---|---|
Storage Conditions | -85 °C to -15 °C |
Format | Lyophilized |
Product Category | Predesigned qPCR assays |
Compatibility | All standard Real-time thermal cyclers |
Target Species | Acinetobacter baumannii |
Sample Material | DNA |
Protocol time | Approx. 60 min (from extracted NA to result) |
Number of targets | Duplex |
Internal Control | No |
Features | Free automatic data analyzer (Fastfinder) |
Detection Method | Probe Based |
- Lyo NZYSupreme qPCR master mix (2x)
- qPCR master mix reconstitution buffer
- Lyo PPMix (10x)
- NTC
- Positive Control
- DNA Internal Extraction Control (IEC)
- qPCR master mix reconstitution buffer
- Lyo PPMix (10x)
- NTC
- Positive Control
- DNA Internal Extraction Control (IEC)
Shipping Conditions | Room Temperature |
---|---|
Storage Conditions | -85 °C to -15 °C |
Format | Lyophilized |
Product Category | Predesigned qPCR assays |
Compatibility | All standard Real-time thermal cyclers |
Target Species | Acinetobacter baumannii |
Sample Material | DNA |
Protocol time | Approx. 60 min (from extracted NA to result) |
Number of targets | Duplex |
Internal Control | No |
Features | Free automatic data analyzer (Fastfinder) |
Detection Method | Probe Based |
Shipping Conditions | Room Temperature |
---|---|
Storage Conditions | -85 °C to -15 °C |
Format | Lyophilized |
Product Category | Predesigned qPCR assays |
Compatibility | All standard Real-time thermal cyclers |
Target Species | Acinetobacter baumannii |
Sample Material | DNA |
Protocol time | Approx. 60 min (from extracted NA to result) |
Number of targets | Duplex |
Internal Control | No |
Features | Free automatic data analyzer (Fastfinder) |
Detection Method | Probe Based |
CoA
Certificate of Analysis